Opened 9 years ago

Closed 8 years ago

#284 closed defect (fixed)

Backend meniscus fit 2dsa incorrect

Reported by: gegorbet Owned by: gegorbet
Priority: major Milestone: future
Component: ultrascan3 Version:
Keywords: review Cc:

Description

The output models from a meniscus fit 2dsa run to an HPC cluster are incorrect. They show a fluctuating pattern of RMSD values that do not pair with the meniscus values in the normal parabolic function.

The symptoms seem to indicate that the meniscus value is not really being changed from iteration to iteration.

Change History (2)

comment:1 Changed 9 years ago by gegorbet

  • Keywords review added
  • Status changed from new to assigned

us_mpi_analysis has been fixed to correctly assign each meniscus in a 2dsa fit-meniscus run. All clusters have been updated.

This ticket is review-ready.

comment:2 Changed 8 years ago by gegorbet

  • Resolution set to fixed
  • Status changed from assigned to closed
Note: See TracTickets for help on using tickets.